VG-30 bitumen ka full form "Viscosity Grade 30" hai — IS 73:2013 ke according yeh paving bitumen hai jiski absolute viscosity 60°C par 2400–3600 poise hoti hai। Iske main limits hain: penetration (25°C) minimum 45, kinematic viscosity (135°C) minimum 350 cSt, softening point minimum 47°C, aur flash point minimum 220°C। IS 73:2013 ke mutabik VG-30 un jagahon ke liye suitable hai jahan 7-din ka average maximum air temperature 38–45°C rehta hai — isi wajah se yeh India mein bahut common general-purpose grade hai.
"VG-30 price per kg" ke baad agar koi doosra sawaal sabse zyada poochha jaata hai, toh woh hai — "VG-30 kya hota hai, aur isi ko itna kyun use karte hain?" Is post mein hum iska seedha jawab denge, IS 73:2013 ke text ke saath.
VG-30 Ka Full Form Aur Matlab (VG-30 Means)
Direct Jawab (40-60 words): VG ka matlab hai Viscosity Grade, aur 30 grade ka number hai। IS 73:2013 mein bitumen ko 60°C par uski viscosity ke hisaab se grade kiya gaya hai। VG-30 ka absolute viscosity range 2400–3600 poise hai, yaani midpoint lagbhag 3000 poise — isi liye grade number lagbhag viscosity ka 1/100 hota hai.
VG-30 Specification Table (IS 73:2013)
| Property | VG-30 Requirement | Test Method |
|---|---|---|
| Penetration at 25°C, 100 g, 5 s (0.1 mm) | 45 min | IS 1203 |
| Absolute viscosity at 60°C (poise) | 2400 – 3600 | IS 1206 (Part 2) |
| Kinematic viscosity at 135°C (cSt) | 350 min | IS 1206 (Part 3) |
| Flash point, Cleveland open cup (°C) | 220 min | IS 1448 [P:69] |
| Solubility in trichloroethylene (%) | 99.0 min | IS 1216 |
| Softening point, R&B (°C) | 47 min | IS 1205 |
| RTFOT residue — viscosity ratio at 60°C | 4.0 max | IS 1206 (Part 2) |
| RTFOT residue — ductility at 25°C (cm) | 40 min | IS 1208 |
Note: IS 73:2013 ke foreword mein likha hai ki ab ductility test specification compliance ke liye mandatory nahi hai, lekin table mein limit di gayi hai — apne project specification mein ductility maangi gayi ho toh test karwayein.
VG-30 Penetration Value — Purani Range Kyun Dikhti Hai?
Direct Jawab (40-60 words): IS 73:2013 (fourth revision) mein VG-30 ka penetration sirf minimum 45 (0.1 mm) specified hai। Tisri revision (2006) mein penetration ki range di jaati thi, aur kai purane notes ya datasheets aaj bhi wahi range (jaise 50–70) dikhate hain। Isliye test report verify karte waqt latest standard ka limit hi use karo.
VG-30 Kyun Use Hota Hai? (Grade Selection by Air Temperature)
IS 73:2013 ka Clause 5 grade selection ko 7-din ke average maximum air temperature se jodta hai:
| Grade | Suitable for 7-day Average Max Air Temperature |
|---|---|
| VG-10 | Below 30°C |
| VG-20 | 30–38°C |
| VG-30 | 38–45°C |
| VG-40 | Above 45°C |
Direct Jawab (40-60 words): VG-30 38–45°C ke design maximum air temperature wale locations ke liye suitable hai, aur India ke bahut se plains aur central regions is band mein aate hain। Isi wajah se VG-30 ek general-purpose paving grade ke roop mein common hai। Tender ya project specification mein jo grade likha ho, wahi final hota hai.
Kuch oil company notes ke according VG-30 purane 60/70 penetration grade ki jagah bhi use ho sakta hai. "Sabse zyada use hone wala grade" ka claim kai suppliers karte hain, lekin iske liye koi independent official statistic mujhe nahi mila — isliye hum ise "widely used / common" kehna hi sahi samajhte hain.
VG-10 vs VG-30 vs VG-40 — Kaunsa Kab?
| Factor | VG-10 | VG-30 | VG-40 |
|---|---|---|---|
| Max air temp suitability | Below 30°C | 38–45°C | Above 45°C |
| Viscosity at 60°C (poise) | 800–1200 | 2400–3600 | 3200–4800 |
| Penetration (min) | 80 | 45 | 35 |
| Softening point (min) | 40°C | 47°C | 50°C |
| Typical fit | Cold / high-altitude regions | General-purpose in hot-plains | Very hot, heavily stressed locations |
Detail ke liye humari VG-10 aur VG-40 wali posts dekhein — cold regions mein VG-10 kyun, aur very hot / heavy-traffic corridors mein VG-40 kyun.
Field Note — 42 Saal Ke Experience Se
Humne dekha hai ki VG-30 ke order mein sabse zyada confusion tab hoti hai jab site par purane "60/70" wale terms chalte rehte hain aur new tender VG-30 maangta hai. Isliye hum apne paperwork mein grade ke saath IS 73:2013 ka reference clearly likhte hain, taaki site engineer ko limits ek hi standard se milane mein dikkat na ho.
Frequently Asked Questions (FAQ)
Q1. VG-30 ka full form kya hai? VG-30 ka full form Viscosity Grade 30 hai। IS 73:2013 ke according bitumen ko 60°C par uski absolute viscosity ke hisaab se grade kiya jaata hai.
Q2. VG-30 ka penetration value kitna hota hai? IS 73:2013 ke Table 1 ke mutabik VG-30 ka penetration at 25°C minimum 45 (0.1 mm) hai. Purane (2006) revision ya kuch datasheets mein range (jaise 50–70) dikh sakti hai.
Q3. VG-30 ki viscosity aur softening point kitna hona chahiye? Absolute viscosity at 60°C: 2400–3600 poise. Kinematic viscosity at 135°C: minimum 350 cSt. Softening point (R&B): minimum 47°C.
Q4. VG-10 aur VG-30 mein kya fark hai? VG-10 softer hai (viscosity 800–1200 poise, penetration min 80) aur kam temperature wale locations (below 30°C) ke liye suitable hai. VG-30 stiffer hai (viscosity 2400–3600 poise, penetration min 45) aur 38–45°C maximum air temperature wale locations ke liye suitable hai.
Q5. Kya VG-30 purane 60/70 grade ki jagah use ho sakta hai? Kai oil company technical notes VG-30 ko 60/70 penetration grade ke replacement ke roop mein batate hain. Lekin final decision tender specification aur design engineer ka hota hai — apne project document mein likhe grade ko hi follow karein.
VG-30 Ka Batch-wise Test Certificate Chahiye? Humse Baat Karein:
Shiva Asphaltic Products Pvt Ltd VG-30 aur doosre VG grades — IS 73:2013 compliant, batch-wise test certificate ke saath Grade selection mein technical help
Email: shivaasphalt@gmail.com 42+ years of family expertise — sahi grade, sahi spec.
Related Articles — यह भी पढ़ें:
- VG-10 Bitumen Complete Guide
- VG-40 Specifications (IS 73:2013)
- Bitumen Price India — IOC/HPCL/BPCL Pricing Mechanism
References
- IS 73:2013, Paving Bitumen — Specification (Fourth Revision), Bureau of Indian Standards — Table 1 and Clause 5
- Indian oil company bitumen technical notes (IOCL, HPCL, BPCL)
Tags: VG 30 Bitumen, VG 30 Means, VG 30 Full Form, Why VG 30 Bitumen Is Used, VG 30 Penetration Value, VG 10 vs VG 30, IS 73 2013, Shiva Asphaltic Products, Bitumen Expert Vikas Poddar 2026

Comments
Post a Comment